Drager Fabius 2000 CE Anesthesia Repair

JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
Contact Now

Drager Fabius 2000 CE Anesthesia Repair

Model Number : Fabius 2000 CE

MOQ : 1

Payment Terms : T/T, Western Union

Delivery Time : about 5 work days

Packaging Details : normal

Price : negotation

Contact Now

Drager Fabius 2000 CE Anesthesia Repair

Whole machine repair or parts in the machine repair.

Drager Fabius 2000 CE Anesthesia Repair

Drager Fabius 2000 CE Anesthesia Repair

Drager Fabius 2000 CE Anesthesia Repair

1 Power Supply PCB
2 Mains filter
3 Mains transformer
4 Front panel (
front frame and membrane keypad)
5 Control knob
6 Power PCB
7 Graphics display and backlighting lamp
8 Control PCB
9 Rechargeable battery or Goldcap capacitor
10 Differential pressure sensor (
flow)
11 Airway pressure sensor (Paw)

Debug Mode (software 1.00)

Accessing the Debug Mode (software 1.00)
The debug mode can be accessed from any operating mode.
• Press the "Menu" key.
• Select "keycode" by turning rotary knob.
• Confirm selection by pressing rotary knob.
The selected numeric code is displayed on black background.
• Select keycode “1” by turning rotary knob one position clockwise.
• Confirm selection by pressing rotary knob.
• Press rotary knob again.

Exiting the Debug Mode (software 1.00)
• Press the “Menu” key.
• Select “keycode” by turning rotary knob.
• Confirm selection by pressing rotary knob.
The selected numeric code is displayed on black background.
• Select keycode “0” by turning rotary knob one position counter-clockwise.
• Confirm selection by pressing rotary knob.
• Press rotary knob again.

Accessing the Debug Mode (software 2.00)
The debug mode can be accessed from any operating mode.
• Press the “Menu” key.
• Select “keycode” by turning rotary knob.
• Confirm selection by pressing rotary knob.
The selected numeric code is displayed on black background.
• Select keycode "1"(debug mode) or "2" (flow curve) by turning rotary knob one
position clockwise.
• Confirm selection by pressing rotary knob.
• Press rotary knob again.

Exiting the Debug Mode (software 2.00)
• Press the "Menu" key.
• Select "keycode" by turning rotary knob.
• Confirm selection by pressing rotary knob.
The selected numeric code is displayed on black background.
• Select keycode “0” by turning rotary knob one position counter-clockwise.
• Confirm selection by pressing rotary knob.
• Press rotary knob again.

DrägerService Mode

DrägerService Mode allows the following actions:
− calibrating the pressure sensor (Paw)
− deleting error log entries
− reading out/resetting elapsed hours meter
− selecting the function (monitor or ventilator or monitor and ventilator)
− initializing Fabius (calibration values, elapsed hours etc.)

Accessing the DrägerService Mode
The DrägerService Mode can only be accessed while Fabius is in the standby mode.
• Press the "Menu" key.
• Select "keycode" by turning rotary knob.
• Confirm by pressing rotary knob.
The respective number is displayed on black background.
• Select keycode “112” by turning rotary knob clockwise.
• Confirm by pressing rotary knob.
An additional screen page is displayed.
Exiting the DrägerService Mode
• Switch the control box off.

More Repair case, welcome to contact at Whatsapp/Tel/Viber/Wechat/Skype 0086-18302034279


Wholesale Drager Fabius 2000 CE Anesthesia Repair from china suppliers

Drager Fabius 2000 CE Anesthesia Repair Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED
*Subject:
*Message:
Characters Remaining: (0/3000)